The gas column Vector operates based on specific principles. It has certain advantages and disadvantages that should be taken into account. Let’s take a closer look at them.
Principle of operation: The gas column Vector uses a flow system to heat water. It operates by passing cold water through a heat exchanger, where it is heated by burning gas. The heated water then flows out of the system, ready to be used.
Advantages: There are several advantages to using the gas column Vector. Firstly, it provides instant hot water, as it heats the water on demand. This eliminates the need for a storage tank and reduces energy consumption. Additionally, it is compact and space-saving, making it suitable for smaller living spaces. Lastly, it is cost-effective, as it only heats the amount of water needed, thus saving energy and reducing utility bills.
Disadvantages: Despite its advantages, there are also some disadvantages to consider. One major drawback is the reliance on a gas supply. If there is a gas shortage or interruption, the gas column Vector will not be able to function. Additionally, it requires professional installation and regular maintenance to ensure proper operation and safety.
Model range: Gas columns Vector offers a wide range of models to choose from, catering to different needs and preferences. Whether you require a compact unit for a small apartment or a more powerful one for a larger household, there is a model available. The various models differ in terms of capacity, energy efficiency, and additional features.
Review of gas water heaters Vector

The Vektor gas column is a highly popular heating option in the Russian market. Although these models are assembled using Chinese spare parts, they maintain a high level of quality thanks to the careful development and testing process overseen by Russian professionals. Some may argue that this type of column is outdated, but it continues to be a relevant choice for many. With its impressive performance, affordable energy source, and compact size compared to other water heaters, it’s no wonder buyers are drawn to these devices. While Vektor’s range of water heaters is limited, their acceptable prices and excellent technical features make them accessible to a wide range of consumers.
The main constituent elements of the gas heater and the principle of its operation
- The copper heat exchanger, which is composed of numerous hollow tubes, serves as the central component and "heart" of the technical apparatus. It functions by allowing cold water to enter and then incorporates gas vapors generated by the burner to heat the cold water within the tubes.
- Irrespective of the specific model, the Vector gas column comes furnished with electrical ignition, thus facilitating the operation of the device and enhancing safety by eliminating the need for a constantly burning igniter with a weak flame.
- When you turn on the faucet, the water-gas unit begins functioning. It is composed of three components: the gas unit itself (constructed from silumin), the adapter that connects the gas and water units (made from a combined alloy), and the water unit (made from brass). The gas valve only activates when the necessary water pressure is present. A regulator is responsible for ensuring the timely supply of gas and controlling the amount of gas to prevent any leaks.
- The gas burner, composed of pressed sheets, initially ignites the air mixture and then helps channel it into a designated combustion chamber.
- All by-products must be eliminated from the gas vent in this chamber. The gas vent is constructed from a thin steel material. To ensure proper functioning, a sensor is inserted in the gas vent to detect any absence of normal draught and subsequently shut down the burner. The burner is effectively stopped when the thermal relay, heated by the hot air, opens. This additional safety precaution is incorporated in the gas heater.
- To prevent overheating, a thermal sensor is strategically positioned at the heat exchanger, where the highest water temperature is detected – the optimal placement. Once the water temperature reaches eighty degrees, the gas supply is automatically turned off, thus ceasing the burner’s operation.
- Pressure regulation is controlled by the fuse. Additionally, the column allows for water drainage.
The gas column produced by Vector is a versatile device that can be used to carry out basic tasks. It can be powered by either natural gas or liquefied gas, and only requires a minimum pressure of 0.2 atmospheres for ignition.

1 – cladding; 2 – frame; 3 – water-gas apparatus; 4 – water control knob; 5 – gas control knob; 6 – electromechanical valve; 7 – burner with collector; 8 – heat exchanger; 9 – water overheating detector; 10 – draft detector; 11 – gas venting mechanism; 12 – electronic burner ignition electrode; 13 – ionization flame control electrode; 14- battery compartment; 15- electronic control unit; 16- digital hot water temperature display; 17- viewing window; 18- microswitch; 19- water block inlet (water supply) with filter; 20- gas block inlet (gas supply) with filter; 21- water outlet; 22- safety valve; 23- hot water temperature sensor.
Advantages of Vector gas boilers
Gas flow water heaters offered by the manufacturer have a range of noticeable advantages, making them highly popular among Russian consumers. Firstly, their affordable price is worth mentioning. Not everyone is willing to spend more than 10 thousand rubles on such equipment, and it’s not always possible to live without it in a private house. In V ektor’s product line, there are models that cost no more than 4000 rubles, while still being capable of meeting all universal needs.
When purchasing this type of equipment, it is also important to consider installation costs. Only qualified professionals should handle the installation of such gas appliances.
The fashionable appearance contributes to maintaining a trendy room design. Due to the fact that the pillar is available in a wide range of colors, it will not draw too much attention and can even serve as a decorative element in some cases. Moreover, the manufacturer Vector is focused on saving space in the room, which is why the gas pillar is compact in size. If, for any reason, the device malfunctions, spare parts of Chinese manufacture can easily be found in any market, and they do not require significant financial investment while prolonging the lifespan of the pillar.
The column is equipped with a user-friendly control system. Contemporary models feature dual knobs for regulating the gas supply to the burner and the flow rate of water passing through the heat exchanger. Certain devices also include a switch to alternate between winter and summer modes. In the default program, all sections of the burner are operational, while in the "Summer" program, some sections are deactivated. If the column has an electronic display, the desired water temperature mode can be viewed on the unit’s body.

Disadvantages of Vector gas boilers
Many users believe that for a small price they are purchasing an exceptional device that comes with all the technological features and functions. Nevertheless, this couldn’t be further from the truth. It is important to realize that due to the utilization of the most cost-effective version of Chinese spare parts, such a device will not have the ability to last for numerous years, unlike comparable models in a higher price range. In certain situations, alternative options for replacing components might be necessary after a certain period of time.
Besides, despite being made of copper, the walls of the heat exchanger are coated with an extremely thin layer of it, which makes them susceptible to burning out over time at high temperatures. As previously stated, the system shuts down only after the water temperature reaches 80 degrees. Consequently, gradual thinning of the walls occurs, rendering the device inoperable.
Furthermore, the lack of additional flame control modules poses an inconvenience. In this situation, the system is regulated solely by automation, which prevents users from making individual adjustments according to their preferences.
Actually, the number of opinions is equal to the number of users. Certain individuals view this speaker as the ultimate purchase, while others regard models from this manufacturer as less than satisfactory. Nevertheless, until one personally experiences using it, they cannot provide an unbiased evaluation.
Model range of Vector gas columns
When discussing Vector gas columns, there are several noteworthy models.
JSD This particular model gained popularity in recent years. The main reason for its high demand is its affordable price, which is set at 4,000 rubles. Additionally, it is worth mentioning its compact size, making it suitable even for small rooms. The inclusion of a digital display has greatly simplified the usage process, along with automatic ignition. The Vektor JSD 20 gas column is available in white, gold, and silver colors.

The JSD 20 column vector

A unique and distinctive vector known as JSD 11-N Column has been developed.

Column Vektor Lux Eco
When it comes to budget-friendly flow water heaters, the Vektor gas columns are the top choice. These units are not only user-friendly, but they also come with a reliable safety system and a sleek design. While the use of lower quality Chinese components helps to bring down the price of this equipment, it does result in a shorter lifespan without repairs. Nevertheless, finding replacement components to restore the performance of the gas column shouldn’t pose much difficulty.
Read more practical tips and expert opinions about modern devices at appliances-news.com. Here you will find answers to questions about any technology.